Angiographic and clinical performance of a paclitaxel-coated balloon compared to a second-generation sirolimus-eluting stent in patients with in-stent restenosis: The BIOLUX randomised controlled trial

  • Christoph J. Jensen*
  • , Gert Richardt
  • , Ralph Tölg
  • , Andrejs Erglis
  • , Carsten Skurk
  • , Werner Jung
  • , Franz Josef Neumann
  • , Karl Stangl
  • , Johannes Brachmann
  • , Dieter Fischer
  • , Julinda Mehilli
  • , Johannes Rieber
  • , Marcus Wiemer
  • , Joachim Schofer
  • , Stefan Sack
  • , Christoph K. Naber
  • *Corresponding author for this work
  • Elisabeth Hospital Essen
  • Segeberger Kliniken GmbH
  • Paula Stradina Clinical University Hospital
  • Charité – Universitätsmedizin Berlin
  • Schwarzwald-Baar Klinikum Villingen-Schwenningen GmbH
  • University of Freiburg
  • Klinikum Coburg
  • University of Münster
  • Ludwig Maximilian University of Munich
  • Klinikum Bogenhausen
  • Ruhr University Bochum
  • Medizinisches Versorgungszentrum Prof. Mathey and Prof. Schofer

Research output: Contribution to journalArticlepeer-review

69 Citations (Scopus)

Abstract

Aims: Although several studies have shown positive outcomes after the use of drug-coated balloons (DCB) for in-stent restenosis (ISR), data on randomised controlled trials versus latest-generation drug-eluting stents (DES) are limited. Therefore, in this randomised trial, we sought to evaluate whether a butyryl-tri-hexyl citrate (BTHC)-based paclitaxel DCB is non-inferior to a biodegradable polymer sirolimus-eluting stent (BP-SES) therapy in patients with ISR in either a bare metal stent (BMS) or DES. Methods and results: A total of 229 patients with ISR in BMS or DES from 13 German centres and one Latvian centre were 2: 1 randomly allocated to DCB (n=157) or DES (n=72). The primary efficacy endpoint was defined as in-stent late lumen loss (LLL) at six months, and the primary safety endpoint was target lesion failure (TLF) at 12 months. LLL in the DCB arm was 0.03±0.40 mm compared to 0.20±0.70 mm in the DES arm (p=0.40). DCB proved to be non-inferior to DES (Δ = -0.17±0.52 mm, 97.5% CI -∞; -0.01]; p<0.0001). At 12 months, Kaplan-Meier TLF estimates were 16.7% in the DCB arm and 14.2% in the DES arm (p=0.65) and remained similar at 18 months (DCB versus DES: 17.4% versus 19.5%, p=0.88). Conclusions: In patients with DES or BMS ISR, treatment with a paclitaxel DCB showed similar LLL at six months and TLF rates up to 18 months compared to a second-generation sirolimus DES.

Original languageEnglish
Pages (from-to)1096-1103
Number of pages8
JournalEuroIntervention
Volume14
Issue number10
DOIs
Publication statusPublished - Nov 2018
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • ACS/NSTE-ACS
  • Diabetes
  • In-stent restenosis
  • Prior PCI
  • Stable angina

Fingerprint

Dive into the research topics of 'Angiographic and clinical performance of a paclitaxel-coated balloon compared to a second-generation sirolimus-eluting stent in patients with in-stent restenosis: The BIOLUX randomised controlled trial'. Together they form a unique fingerprint.

Cite this