Skip to main navigation Skip to search Skip to main content

Light scattering in artificial fog and simulated with light scattering filter

  • Laboratoire Régional des Ponts et Chaussées

Research output: Contribution to journal › Article › peer-review

6 Citations (Scopus)

Abstract

Disability glare, affecting e.g. road safety at night, may result either from intraocular light scattering or from external conditions such as fog. Measurements were made of light scattering in fog and compared with intraocular straylight data for normal eyes and eyes with simulated cataract. All measurements were made with a direct compensation flicker method. To estimate light scattering levels in fog, straylight measurements were carried in a fog chamber for different densities of fog. Density was characterized by the meteorological term visibility V and ranged from 7 to 25. Test distance for measurements in the fog was constant at 5 m. Cataract eye conditions were simulated by placing a light scattering polymer dispersed liquid crystal (PDLC) filter with scatterers of submicron size in front of the normal eye. All measurements were made using each of three broad-band color stimuli - red, green and blue (produced either with LEDs or a color CRT monitor). Differences were found in both the level and the spectral characteristics of scattering under the different conditions. The measured values of the straylight parameter, s, in artificial fog showed no noticeable spectral dependence at any visibility range. Increasing the visibility range caused an exponential decrease in the straylight. Intraocular straylight measured with the clear eye showed an increase at the red and blue ends of the spectrum as compared to the green. Straylight measured using PDLC plates with different transparency levels showed a spectral dependence which decreased with wavelength. The scattering introduced by the PDLC plate therefore failed to give a valid simulation of cataract and fog conditions for polychromatic stimuli, due to its erroneous spectral dependence.

Original languageEnglish
Pages (from-to)351-356
Number of pages6
JournalOphthalmic and Physiological Optics
Volume29
Issue number3
DOIs
Publication statusPublished - May 2009

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being
  2. SDG 11 - Sustainable Cities and Communities
    SDG 11 Sustainable Cities and Communities

Keywords

  • Cataract
  • Fog
  • Intraocular light scattering
  • Polymer dispersed liquid crystal plate
  • Spectral dependence of straylight

Fingerprint

Dive into the research topics of 'Light scattering in artificial fog and simulated with light scattering filter'. Together they form a unique fingerprint.

Cite this