Skip to main navigation Skip to search Skip to main content

One-year outcomes in unselected patients treated with a thinstrut, platinum-chromium, paclitaxel-eluting stent: Primary endpoint results from the TAXUS Element European postapproval surveillance study (TE-PROVE)

  • Corrado Tamburino
  • , Davide Capodanno*
  • , Andrejs Erglis
  • , Ian B.A. Menown
  • , Iván G. Horváth
  • , Raul Moreno
  • , Timothy J. Gilbert
  • , James J. Crowley
  • , Paolo Calabria
  • , Dominic J. Allocco
  • , Keith D. Dawkins
  • *Corresponding author for this work
  • University of Catania
  • Paula Stradina Clinical University Hospital
  • Craigavon Cardiac Centre
  • University of Pecs
  • Hospital Universitario La Paz
  • Norfolk and Norwich University Hospitals NHS Foundation Trust
  • University of Galway
  • Misericordia Hospital
  • Boston Scientific Corporation

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

Aims: To evaluate clinical outcomes in patients receiving the next-generation, paclitaxel-eluting, platinumchromium TAXUS Element stent in a real-world setting. The PERSEUS Workhorse and Small Vessel studies showed positive results with the TAXUS Element stent in a clinical trial setting. Methods and results: TE-PROVE was a prospective, open-label, multicentre, "all-comers" study which enrolled 1,014 patients at 37 European sites. Follow-up was at 30 days, six months and one year, and will continue annually up to five years. The primary endpoint was overall and stent-related target vessel failure (TVF), defined as cardiac death, target vessel-related myocardial infarction (MI) and target vessel revascularisation (TVR) at one year post implantation. Secondary endpoints included the components of TVF, allcause mortality, and ARC definite/probable stent thrombosis. Follow-up was available in 97.3% (987/1,014) of patients. Patients were 75.0% male (760/1,014), mean age was 65.1±10.8 years, 25.5% had medically treated diabetes (259/1,014), and 10.7% (109/1,014) were treated for STEMI. At baseline, mean lesion length among 1,299 treated lesions was 19.8±12.0 mm and mean reference vessel diameter was 3.1±0.5 mm. At one year, the rate of TVF (primary endpoint) was 6.0% (59/987) overall; 3.7% (37/987) of TVF events were stent-related. Cardiac death was 0.7% (7/987), target vessel-related MI was 1.1% (11/987), and TVR was 4.7% (46/987). All-cause death occurred in 1.2% (12/987) of patients and ARC definite/probable ST was 0.5% (5/987). Conclusions: The primary endpoint results from the TE-PROVE registry demonstrate good performance and safety for the TAXUS Element paclitaxel-eluting stent at one year in everyday clinical practice. Clinical Trial Registration Information: NCT01242696.

Original languageEnglish
Pages (from-to)1261-1266
Number of pages6
JournalEuroIntervention
Volume10
Issue number11
DOIs
Publication statusPublished - 1 Mar 2015
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Drug-eluting stent
  • Paclitaxel
  • Platinumchromium

Fingerprint

Dive into the research topics of 'One-year outcomes in unselected patients treated with a thinstrut, platinum-chromium, paclitaxel-eluting stent: Primary endpoint results from the TAXUS Element European postapproval surveillance study (TE-PROVE)'. Together they form a unique fingerprint.

Cite this