Abstract
Radiation effects on highly oriented antiferroelectric (AFE) PbZrO 3 (PZ) films with a thickness of approximately 400 nm are investigated in view of their possible application as a temperature sensitive element in a new bolometer system for fusion devices like ITER. The films were prepared by pulsed laser deposition (PLD). The dielectric constant was measured in the frequency range from 1 to 250 kHz in a stepwise cooling mode (∼2 °C min-1) from 400 °C to room temperature before and after irradiation to a fast neutron fluence of 2 × 1022 m -2 (E > 0.1 MeV). After irradiation, the films were annealed in several steps up to ∼400 °C to remove the radiation-induced defects. The results are discussed in terms of two kinds of radiation effects, i.e. structural defects (oxygen vacancies) and radiation-induced charges, trapped at defect structures. The measurements show significant differences to sol-gel PZ thin films, which is mainly explained by the high quality of the PLD films.
| Original language | English |
|---|---|
| Pages (from-to) | 833-836 |
| Number of pages | 4 |
| Journal | Fusion Engineering and Design |
| Volume | 66-68 |
| DOIs | |
| Publication status | Published - Sept 2003 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Keywords
- Alternative bolometer system
- Antiferroelectric PZ thin films
- Radiation-induced defects
Fingerprint