Skip to main navigation Skip to search Skip to main content

Reliability and validity of the new VikingSlice software for computed tomography body composition analysis

  • Imanta Ozola-Zālīte
  • , Esben Bolvig Mark
  • , Tomas Gudauskas
  • , Vladimir Lyadov
  • , Søren Schou Olesen
  • , Asbjørn Mohr Drewes
  • , Aldis Pukitis*
  • , Jens Brøndum Frokjær
  • *Corresponding author for this work
  • Paula Stradina Clinical University Hospital
  • Aalborg University
  • Clinical Hospital N1 “MEDSI”

Research output: Contribution to journal › Article › peer-review

25 Citations (Scopus)

Abstract

Background/objectives: Body composition assessment by computed tomography (CT) is increasingly used for diagnostic and prognostic purposes in various patient groups. This study aimed to compare the reliability and validity of a newly in-house developed segmentation software VikingSlice against a commercial software (SliceOMatic) for quantification of adipose tissue and skeletal muscle cross-sectional areas (CSA). Subjects/methods: Fifty abdominal CT sets from chronic pancreatitis patients were analyzed (mean age 49, range 27–84 years; 38 males). Soft tissue CSAs at level of 4th lumbar vertebra were assessed by measuring standard Hounsfield unit threshold definitions with both softwares. Analysis with VikingSlice included automatic segmentation of interested region with subsequent manual corrections. Analysis with SliceOMatic included manual segmentation of each area. Same investigator measured CSAs using both programs. Inter-observer reliability of CSAs measurements with VikingSlice were assessed by comparing results from two independent investigators. Measurements were compared using the intra-class correlation coefficient (ICC), coefficient of variation (CV), Jaccard index and Bland–Altman analyses. Results: The inter-observer reliability of VikingSlice was excellent (CV 3.4–15.4%, ICC 0.979–0.999, Jaccard index 0.68–0.98). Validity was high (CV 1.6–10.2%, ICC 0.950–0.997) for measurements by SliceOmatic and VikingSlice. The findings were supported in the Bland–Altman plots. The reliability study had small average differences with means of soft tissue compartments in range −2.29 cm 2 to 1.56 cm 2 ; average differences between both softwares were −1.28 cm 2 to 0.31 cm 2 . Conclusions: The in-house developed software VikingSlice was fast and showed good reliability that is comparable with commercial software in its utility to estimate adipose tissue and skeletal muscle CSAs.

Original languageEnglish
Pages (from-to)54-61
Number of pages8
JournalEuropean Journal of Clinical Nutrition
Volume73
Issue number1
DOIs
Publication statusPublished - 1 Jan 2019
Externally publishedYes

Fingerprint

Dive into the research topics of 'Reliability and validity of the new VikingSlice software for computed tomography body composition analysis'. Together they form a unique fingerprint.

Cite this