Skip to main navigation Skip to search Skip to main content

Safety and efficacy of a bioabsorbable polymer-coated, everolimus-eluting coronary stent in patients with diabetes: The EVOLVE II diabetes substudy

  • Dean J. Kereiakes*
  • , Ian T. Meredith
  • , Monica Masotti
  • , Didier Carrié
  • , Raul Moreno
  • , Andrejs Erglis
  • , Shamir R. Mehta
  • , Simon Elhadad
  • , Jacques Berland
  • , Bernardo Stein
  • , Juhani Airaksinen
  • , R. Lee Jobe
  • , Arthur Reitman
  • , Luc Janssens
  • , Thomas Christen
  • , Keith D. Dawkins
  • , Stephan Windecker
  • *Corresponding author for this work
  • Health Alliance
  • Monash Medical Centre
  • University of Barcelona
  • CHU de Toulouse
  • Hospital Universitario La Paz
  • Paula Stradina Clinical University Hospital
  • Hamilton Health Sciences
  • Centre Hospitalier de Lagny
  • Clinique Saint-Hilaire - Centre Frédéric Joliot
  • Morton Plant Mease Baycare Health System
  • University of Turku
  • UNC Rex Healthcare
  • Wellstar Kennestone Hospital
  • Imelda Hospital
  • Boston Scientific Corporation
  • University of Bern

Research output: Contribution to journalArticlepeer-review

23 Citations (Scopus)

Abstract

Aims: Bioabsorbable polymer drug-eluting stents (DES) may reduce the inflammation and delayed healing associated with some permanent polymer-coated DES. Whether late clinical outcomes are improved, particularly among patients with medically treated diabetes, is unknown. Therefore, we analysed outcomes from a pre-specified substudy of the EVOLVE II trial to evaluate the safety and effectiveness of the SYNERGY stent in patients with diabetes mellitus. Methods and results: SYNERGY is a thin-strut, platinum-chromium everolimus-eluting stent with an ultra-thin bioabsorbable poly(DL-lactide-co-glycolide) abluminal polymer. The EVOLVE II randomised, controlled trial proved the non-inferiority of the SYNERGY versus the PROMUS Element Plus stent for one-year target lesion failure (TLF: ischaemia-driven target lesion revascularisation [ID-TLR], target vessel myocardial infarction [TVMI], or cardiac death). The pre-specified EVOLVE II diabetes substudy prospectively pooled randomised patients with diabetes (N=263) with a sequential single-arm diabetic cohort (n=203). The substudy primary endpoint was one-year TLF compared with a pre-specified performance goal (14.5%). The primary endpoint occurred in 7.5% of SYNERGY-treated patients with diabetes, significantly less than the performance goal (p<0.0001). The two-year rate of TLF was 11.2% (cardiac death 1.5%, TVMI 6.4%, ID-TLR 6.8%) and definite/probable stent thrombosis occurred in 1.1% of patients. Conclusions: The EVOLVE II diabetes substudy demonstrates the efficacy and safety of the SYNERGY stent in patients with medically treated diabetes. Clinical Trial Registration Information: NCT01665053 (http://clinicaltrials.gov/).

Original languageEnglish
Pages (from-to)1987-1994
Number of pages8
JournalEuroIntervention
Volume12
Issue number16
DOIs
Publication statusPublished - Mar 2017
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Safety and efficacy of a bioabsorbable polymer-coated, everolimus-eluting coronary stent in patients with diabetes: The EVOLVE II diabetes substudy'. Together they form a unique fingerprint.

Cite this