Skip to main navigation Skip to search Skip to main content

Significance of a single-time-point somatostatin receptor SPECT/multiphase CT protocol in the diagnostic work-up of gastroenteropancreatic neuroendocrine neoplasms

  • Juri Ruf
  • , Friederike Von Wedel
  • , Christian Furth
  • , Timm Denecke
  • , Lars Stelter
  • , Ingo G. Steffen
  • , Kerstin Schütte
  • , Jörg Arend
  • , Gerhard Ulrich
  • , Silke Klose
  • , Jan Bornschein
  • , Ivalya Apostolova
  • , Holger Amthauer*
  • *Corresponding author for this work
  • Otto von Guericke University Magdeburg
  • University of Freiburg
  • Charité – Universitätsmedizin Berlin

Research output: Contribution to journalArticlepeer-review

7 Citations (Scopus)

Abstract

This prospective study compared a 1-d SPECT/CT protocol with the commonly used 3-d protocol for somatostatin receptor scintigraphy in patients with gastroenteropancreatic neuroendocrine neoplasms. Additionally, the influence of SPECT/CT on patient management was evaluated. Methods: From October 2011 to October 2012, all gastroenteropancreatic neuroendocrine neoplasm patients undergoing restaging with somatostatin receptor scintigraphy on a modern SPECT/CT device were enrolled in this study. The protocol consisted of planar imaging at 4, 24, and 48 h; low-dose SPECT/CT at 24 and 48 h; diagnostic CT at 24 h using a triple-phase delay after administration of contrast; and diagnostic SPECT/CT at 24 h. All components of the imaging data were reassessed by 3 masked interpreters. The results were compared with a reference standard based on all clinical, imaging, and histopathology follow-up data available (follow-up range, 24-36 mo; mean, 29.9 mo). The reference standard was defined by a study-specific interdisciplinary tumor board that also reassessed treatment decisions. Results: Thirty-one patients were eligible for analysis (18 men and 13 women; mean age, 60.4 y). Ten had no imaging signs of disease and remained disease-free during follow-up. Twenty-one had persistent or recurrent disease (82 lesions: 24 in the liver, 21 in the lymph nodes, 16 in bone, 12 in the pancreas, and 9 in other locations). The respective lesion detection rates for interpreters 1, 2, and 3 were 51.9%, 49.4%, and 71.6% for low-dose SPECT/CT at 24 h; 51.9%, 55.6%, and 67.9% for low-dose SPECT/CT at 48 h; 63.0%, 70.4%, and 85.2% for diagnostic CT; and 77.8%, 84.0%, and 88.9% for diagnostic SPECT/CT. Interobserver agreement was moderate for diagnostic SPECT/CT (? 5 0.44), diagnostic CT (? 5 0.43), low-dose SPECT/CT at 48 h (? 5 0.61), and low-dose SPECT/CT at 24 h (? 5 0.55). For planar imaging, interobserver agreement was fair after 48 h (? 5 0.36) and 24 h (? 5 0.38) and moderate after 4 h (? 5 0.42). Every lesion detectable on planar imaging or lowdose SPECT/CT was also detectable on diagnostic SPECT/CT. The CT and SPECT components of diagnostic SPECT/CT strongly complemented each other, as 34 of 82 lesions (41.4%) were detected on only the CT component or only the SPECT component. Therapeutic management was influenced by the diagnostic SPECT/CT interpretation in 8 of 31 patients (25.8%). Conclusion: The highest detection rates were achieved by diagnostic SPECT/CT. Thus, a more patient-friendly 1-d protocol is feasible. Furthermore, multiphase SPECT/CT affected management in about a quarter of patients.

Original languageEnglish
Pages (from-to)180-185
Number of pages6
JournalJournal of Nuclear Medicine
Volume57
Issue number2
DOIs
Publication statusPublished - 1 Feb 2016
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Multiphase CT
  • Neuroendocrine neoplasm
  • Scintigraphy
  • Somatostatin receptor
  • SPECT/CT

Fingerprint

Dive into the research topics of 'Significance of a single-time-point somatostatin receptor SPECT/multiphase CT protocol in the diagnostic work-up of gastroenteropancreatic neuroendocrine neoplasms'. Together they form a unique fingerprint.

Cite this