Building envelopes under various climates behave differently, in this paper the actual thermal transmittance or U-value of five different wall assemblies are evaluated and compared with values, calculated using standard EN ISO 6946. The experiment is carried out in five test buildings with equal spatial orientation, the same ceiling and floor assemblies as well as the same windows and doors mounted in each building. The thermal transmittances for these partitions are assumed to be well known and therefore, by knowing temperature difference and heat sources inside the building, the thermal transmittance of wall assembly can be calculated. It is shown that for small buildings the corner effects are of great importance and therefore a more precise calculation of them are done.

Original languageEnglish
Pages (from-to)207-213
Number of pages7
JournalEnergy Procedia
Volume147
DOIs
Publication statusPublished - 2018
Event2018 International Scientific Conference on Environmental and Climate Technologies, CONECT 2018 - Riga, Latvia
Duration: 16 May 2018 → 18 May 2018

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy
  2. SDG 9 - Industry, Innovation, and Infrastructure
    SDG 9 Industry, Innovation, and Infrastructure
  3. SDG 12 - Responsible Consumption and Production
    SDG 12 Responsible Consumption and Production

Keywords

  • U-value
  • energy efficiency
  • thermal bridges
  • thermal mass

Fingerprint

Dive into the research topics of 'Wall assemblies U-value calculation in test buildings using constant power heating'. Together they form a unique fingerprint.

Cite this