Pāriet uz galveno navigāciju Pāriet uz meklēšanu Pāriet uz galveno saturu

Analytical, thermodynamical and kinetic characteristics of photoluminescence immunosensor for the determination of Ochratoxin A

  • Roman Viter*
  • , Maryna Savchuk
  • , Igor Iatsunskyi
  • , Zuzanna Pietralik
  • , Nikolay Starodub
  • , Nelya Shpyrka
  • , Almira Ramanaviciene
  • , Arunas Ramanavicius
  • *Šī darba korespondējošais autors
  • National University of Life and Environmental Sciences of Ukraine
  • Adam Mickiewicz University in Poznań
  • Vilnius University

Zinātniskās darbības rezultāts: Devums žurnālam › Zinātniskais raksts (žurnālā) › koleģiāli recenzēts

120 Atsauces (Scopus)

Kopsavilkums

Ochratoxin A (OTA) is one of the most widespread and dangerous food contaminants. Therefore, rapid, label-free and precise detection of low OTA concentrations requires novel sensing elements with advanced bio-analytical properties. In the present paper we report photoluminescence (PL) based immunosensor for the detection of OTA. During the development of immunosensor photoluminescent ZnO nanorods (ZnO-NRs) were deposited on glass substrate. Then the ZnO-NRs were silanized and covalently modified by Protein-A (Glass/ZnO-NRs/Protein-A). The latest structure was modified by antibodies against OTA (Anti-OTA) in order to form OTA-selective layer (Glass/ZnO-NRs/Protein-A/Anti-OTA). In order to improve immunosensors selectivity the surface of Glass/ZnO-NRs/Protein-A/Anti-OTA was additionally blocked by BSA. Formed Glass/ZnO-NRs/Protein-A/BSA&Anti-OTA structures were integrated within portable fiber optic detection system, what is important for the development of low cost and portable immunosensors. The immunosensor has been tested in a wide range of OTA concentrations from 10−4 ng/ml until 20 ng/ml. Interaction isotherms were derived from analytical signals of immunosensor. Association constant and Gibbs free energy for the interaction of Glass/ZnO-NRs/Protein-A/Anti-OTA with OTA were calculated, analyzed and compared with some other related results. Sensitivity range and limit of detection were determined as 0.1–1 ng/ml and 10−2 ng/ml, respectively. Interaction kinetics of ZnO-NRs with OTA was evaluated. Response time of the immunosensor toward OTA was in the range of 500–800 s. Some insights related to the mechanism of PL-signal generation are proposed and discussed.

OriģinālvalodaAngļu
Lapas (no-līdz)237-243
Lapu skaits7
ŽurnālsBiosensors and Bioelectronics
Sējums99
DOIs
Publikācijas statussPublicēts - 15 janv. 2018

Nospiedums

Uzziniet vairāk par pētniecības tēmām “Analytical, thermodynamical and kinetic characteristics of photoluminescence immunosensor for the determination of Ochratoxin A”. Kopā tie veido unikālu nospiedumu.

Citēt šo