Detection of Escherichia coli in biofilms from pipe samples and coupons in drinking water distribution networks

  • T. Juhna*
  • , D. Birzniece
  • , S. Larsson
  • , D. Zulenkovs
  • , A. Sharipo
  • , N. F. Azevedo
  • , F. Ménard-Szczebara
  • , S. Castagnet
  • , C. Féliers
  • , C. W. Keevil
  • *Šī darba korespondējošais autors
  • Riga Technical University
  • Latvian Institute of Organic Synthesis
  • University of Minho
  • University of Southampton
  • Veolia Environnement

Zinātniskās darbības rezultāts: Devums žurnālamZinātniskais raksts (žurnālā)koleģiāli recenzēts

119 Atsauces (Scopus)

Kopsavilkums

Fluorescence in situ hybridization (FISH) was used for direct detection of Escherichia coli on pipe surfaces and coupons in drinking water distribution networks. Old cast iron main pipes were removed from water distribution networks in France, England, Portugal, and Latvia, and E. coli was analyzed in the biofilm. In addition, 44 flat coupons made of cast iron, polyvinyl chloride, or stainless steel were placed into and continuously exposed to water on 15 locations of 6 distribution networks in France and Latvia and examined after 1 to 6 months exposure to the drinking water. In order to increase the signal intensity, a peptide nucleic acid (PNA) 15-mer probe was used in the FISH screening for the presence or absence of E. coli on the surface of pipes and coupons, thus reducing occasional problems of autofluorescence and low fluorescence of the labeled bacteria. For comparison, cells were removed from the surfaces and examined with culture-based or enzymatic (detection of β-D-glucuronidase) methods. An additional verification was made by using PCR. Culture method indicated presence of E. coli in one of five pipes, whereas all pipes were positive with the FISH methods. E. coli was detected in 56% of the coupons using PNA FISH, but no E. coli was detected using culture or enzymatic methods. PCR analyses confirmed the presence of E. coli in samples that were negative according to culture-based and enzymatic methods. The viability of E. coli cells in the samples was demonstrated by the cell elongation after resuscitation in low-nutrient medium supplemented with pipemidic acid, suggesting that the cells were present in an active but nonculturable state, unable to grow on agar media. E. coli contributed to ca. 0.001 to 0.1% of the total bacterial number in the samples. The presence and number of E. coli did not correlate with any of physical and/or chemical characteristic of the drinking water (e.g., temperature, chlorine, or biodegradable organic matter concentration). We show here that E. coli is present in the biofilms of drinking water networks in Europe. Some of the cells are metabolically active but are often not detected due to limitations of traditionally used culture-based methods, indicating that biofllm should be considered as a reservoir that must be investigated further in order to evaluate the risk for human health.

OriģinālvalodaAngļu
Lapas (no-līdz)7456-7464
Lapu skaits9
ŽurnālsApplied and Environmental Microbiology
Sējums73
Izdevuma numurs22
DOIs
Publikācijas statussPublicēts - nov. 2007
Ārēji publicēts

ANO IAM

Šis izpildes rezultāts palīdz sasniegt šādus ANO ilgtspējīgas attīstības mērķus (IAM)

  1. 3. IAM — Laba Veselība un Labbūtība
    3. IAM — Laba Veselība un Labbūtība
  2. 6. IAM — Tīrs Ūdens un Sanitārija
    6. IAM — Tīrs Ūdens un Sanitārija

Nospiedums

Uzziniet vairāk par pētniecības tēmām “Detection of Escherichia coli in biofilms from pipe samples and coupons in drinking water distribution networks”. Kopā tie veido unikālu nospiedumu.

Citēt šo