Different Cell Viability Assays Reveal Inconsistent Results After Bleomycin Electrotransfer In Vitro

  • Baltramiejus Jakštys
  • , Paulius Ruzgys
  • , Mindaugas Tamošiūnas
  • , Saulius Šatkauskas*
  • *Šī darba korespondējošais autors
  • Vytautas Magnus University

Zinātniskās darbības rezultāts: Devums žurnālam › Zinātniskais raksts (žurnālā) › koleģiāli recenzēts

42 Atsauces (Scopus)

Kopsavilkums

The aim of this study was to compare different and commonly used cell viability assays after CHO cells treatment with anticancer drug bleomycin (20 nM), high voltage (HV) electric pulses (4 pulses, 1200 V/cm, 100 µs, 1 Hz), and combination of bleomycin and HV electric pulses. Cell viability was measured using clonogenic assay, propidium iodide (PI) assay, MTT assay, and employing flow cytometry modality to precisely count cells in definite volume of the sample (flow cytometry assay). Results showed that although clonogenic cell viability drastically decreased correspondingly to 57 and 3 % after cell treatment either with HV pulses or combination of bleomycin and HV pulses (bleomycin electrotransfer), PI assay performed ~15 min after the treatments indicated nearly 100 % cell viability. MTT assay performed at 6–72 h time points after these treatments revealed that MTT cell viability is highly dependent on evaluation time point and decreased with later evaluation time points. Nevertheless, in comparison to clonogenic cell viability, MTT cell viability after bleomycin electrotransfer at all testing time points was significantly higher. Flow cytometry assay if used at later times, 2–3 days after the treatment, allowed reliable evaluation of cell viability. In overall, our results showed that in order to estimate cell viability after cell treatment with combination of the bleomycin and electroporation the most reliable method is clonogenic assay. Improper use of PI and MTT assays can lead to misinterpretation of the experimental results.

OriģinālvalodaAngļu
Lapas (no-līdz)857-863
Lapu skaits7
ŽurnālsJournal of Membrane Biology
Sējums248
Izdevuma numurs5
DOIs
Publikācijas statussPublicēts - 13 okt. 2015
Ārēji publicētsJā

ANO IAM

Šis izpildes rezultāts palīdz sasniegt šādus ANO ilgtspējīgas attīstības mērķus (IAM)

  1. 3. IAM — Laba Veselība un Labbūtība
    3. IAM — Laba Veselība un Labbūtība

Nospiedums

Uzziniet vairāk par pētniecības tēmām “Different Cell Viability Assays Reveal Inconsistent Results After Bleomycin Electrotransfer In Vitro”. Kopā tie veido unikālu nospiedumu.

Citēt šo