TY - JOUR
T1 - Effects of the sources of calcium and phosphorus on the structural and functional properties of ceramic coatings on titanium dental implants produced by plasma electrolytic oxidation
AU - Kyrylenko, Sergiy
AU - Warchoł, Fiona
AU - Oleshko, Oleksandr
AU - Husak, Yevheniia
AU - Kazek-Kęsik, Alicja
AU - Korniienko, Viktoriia
AU - Deineka, Volodymyr
AU - Sowa, Maciej
AU - Maciej, Artur
AU - Michalska, Joanna
AU - Jakóbik-Kolon, Agata
AU - Matuła, Izabela
AU - Basiaga, Marcin
AU - Hulubnycha, Viktoriia
AU - Stolarczyk, Agnieszka
AU - Pisarek, Marcin
AU - Mishchenko, Oleg
AU - Pogorielov, Maksym
AU - Simka, Wojciech
N1 - Publisher Copyright:
© 2020 Elsevier B.V.
PY - 2021/2
Y1 - 2021/2
N2 - Plasma Electrolytic Oxidation (PEO) is as a promising technique to modify metal surfaces by application of oxide ceramic coatings with appropriate physical, chemical and biological characteristics. Therefore, objective of this research was to find the simplest settings, yet able to produce relevant bioactive implant surfaces layers on Ti implants by means of PEO. We show that an electrolyte containing potassium dihydrogen phosphate as a source of P and either calcium hydroxide or calcium formate as a source of Ca in combination with a chelating agent, ethylenediamine tetraacetic acid (EDTA), is suitable for PEO to deliver coatings with desired properties. We determined surface morphology, roughness, wettability, chemical and phase composition of titanium after the PEO process. To investigate biocompatibility and bacterial properties of the PEO oxide coatings we used microbial and cell culture tests. The electrolyte based on Ca(OH)2 and EDTA promotes active crystallization of apatites after PEO processing of the Ti implants. The PEO layers can increase electrochemical corrosion resistance. The PEO can be potentially used for development of bioactive surfaces with increased support of eukaryotic cells while inhibiting attachment and growth of bacteria without use of antibacterial agents.
AB - Plasma Electrolytic Oxidation (PEO) is as a promising technique to modify metal surfaces by application of oxide ceramic coatings with appropriate physical, chemical and biological characteristics. Therefore, objective of this research was to find the simplest settings, yet able to produce relevant bioactive implant surfaces layers on Ti implants by means of PEO. We show that an electrolyte containing potassium dihydrogen phosphate as a source of P and either calcium hydroxide or calcium formate as a source of Ca in combination with a chelating agent, ethylenediamine tetraacetic acid (EDTA), is suitable for PEO to deliver coatings with desired properties. We determined surface morphology, roughness, wettability, chemical and phase composition of titanium after the PEO process. To investigate biocompatibility and bacterial properties of the PEO oxide coatings we used microbial and cell culture tests. The electrolyte based on Ca(OH)2 and EDTA promotes active crystallization of apatites after PEO processing of the Ti implants. The PEO layers can increase electrochemical corrosion resistance. The PEO can be potentially used for development of bioactive surfaces with increased support of eukaryotic cells while inhibiting attachment and growth of bacteria without use of antibacterial agents.
KW - Anodization
KW - Bioactive surface
KW - Biocompatibility
KW - Dental implant
KW - Hydroxyapatite
KW - Osseointegration
UR - https://www.scopus.com/pages/publications/85092925230
U2 - 10.1016/j.msec.2020.111607
DO - 10.1016/j.msec.2020.111607
M3 - Article
C2 - 33321651
AN - SCOPUS:85092925230
SN - 0928-4931
VL - 119
JO - Materials Science and Engineering C
JF - Materials Science and Engineering C
M1 - 111607
ER -