Efficiency and dynamic range of the photostimulable x-ray storage material KBr:In

  • Irena Pļaviņa*
  • , Anatoli I. Popov
  • , Aija Tale
  • , A. Kalniņš
  • *Šī darba korespondējošais autors
  • University of Latvia

Zinātniskās darbības rezultāts: Devums žurnālamKonferences zinātniskais rakstskoleģiāli recenzēts

1 Atsauce (Scopus)

Kopsavilkums

By calibrating the photostimulated luminescence (PSL) response with the known intensity of a standard light source, efficiency of the KBr:In powder material to the x- ray bremsstrahlung exposure at room temperature is estimated. At 44 and 85 kV voltages on the x-ray tube, the values of (8 plus or minus 2) multiplied by 105 and (18 plus or minus 4) multiplied by 10 5 photons from 1 mm2 area of the 1 mm thick material are obtained as PSL responses on a 1 mR x-ray exposure, respectively. Under an assumption of the uniform x-ray excitation within the material, the maximum values for the x-ray irradiation dose and the PSL response both corresponding to the upper limit of linearity range are tentatively appraised, using the data for PSL response saturation under UV-irradiation.

OriģinālvalodaAngļu
Lapas (no-līdz)74-78
Lapu skaits5
ŽurnālsProceedings of SPIE - The International Society for Optical Engineering
Sējums2967
DOIs
Publikācijas statussPublicēts - 1997
PasākumsOptical Inorganic Dielectric Materials and Devices - Riga, Latvija
Ilgums: 26 aug. 199626 aug. 1996