Pāriet uz galveno navigāciju Pāriet uz meklēšanu Pāriet uz galveno saturu

Electrolyses model development for metal/electrolyte interface: Testing with microrespiration sensors

  • Martins Vanags*
  • , Janis Kleperis
  • , Gunars Bajars
  • *Šī darba korespondējošais autors

Zinātniskās darbības rezultāts: Devums žurnālamZinātniskais raksts (žurnālā)koleģiāli recenzēts

16 Atsauces (Scopus)

Kopsavilkums

Initial process of electrolysis is investigated using platinum and tungsten wires as hydrogen electrodes and inductive kickback voltage peak based power unit. Microelectrodes are used to determine concentrations of dissolved hydrogen and pH close to wire electrodes. It is observed that concentration of dissolved hydrogen increases faster on tungsten electrode as on platinum. Authors explain this fact with differences of hydrogen evolution reaction on both materials - inductive kickback voltage peak power unit is supplying very short voltage pulses with limited energy what is enough only for hydrogen adsorption on platinum electrode, but is sufficient for full hydrogen evolution reaction on tungsten electrode.

OriģinālvalodaAngļu
Lapas (no-līdz)1316-1320
Lapu skaits5
ŽurnālsInternational Journal of Hydrogen Energy
Sējums36
Izdevuma numurs1
DOIs
Publikācijas statussPublicēts - janv. 2011

ANO IAM

Šis izpildes rezultāts palīdz sasniegt šādus ANO ilgtspējīgas attīstības mērķus (IAM)

  1. 7. IAM — Tīra Enerģija par Pieejamu Cenu
    7. IAM — Tīra Enerģija par Pieejamu Cenu

Nospiedums

Uzziniet vairāk par pētniecības tēmām “Electrolyses model development for metal/electrolyte interface: Testing with microrespiration sensors”. Kopā tie veido unikālu nospiedumu.

Citēt šo