Kopsavilkums
The effectiveness of fastening of high-strength unidirectional CFRP/epoxy rods in potted anchors was investigated experimentally. The rods had splitted ends, in which duralumin wedges were glued. The experiments, performed for three types of contact between the composite rods and the potted material, showed that the most effective were full adhesion and adhesion-friction contacts, when the maximum load-carrying capacity of CFRP rods under tension could be reached. The full friction contact was ineffective because of the shear failure of CFRP rods inside the anchorage zone.
| Oriģinālvaloda | Angļu |
|---|---|
| Lapas (no-līdz) | 595-604 |
| Lapu skaits | 10 |
| Žurnāls | Mechanics of Composite Materials |
| Sējums | 49 |
| Izdevuma numurs | 6 |
| DOIs | |
| Publikācijas statuss | Publicēts - janv. 2014 |
OECD Zinātnes nozare
- 1.3 Fizika un astronomija
Nospiedums
Uzziniet vairāk par pētniecības tēmām “Fastening of a high-strength composite rod with a splitted and wedged end in a potted anchor 1. Experimental investigation”. Kopā tie veido unikālu nospiedumu.Citēt šo
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver