TY - JOUR
T1 - Nitrilotriacetic Acid Improves Plasma Electrolytic Oxidation of Titanium for Biomedical Applications
AU - Kyrylenko, Sergiy
AU - Sowa, Maciej
AU - Kazek-Kęsik, Alicja
AU - Stolarczyk, Agnieszka
AU - Pisarek, Marcin
AU - Husak, Yevheniia
AU - Korniienko, Viktoriia
AU - Deineka, Volodymyr
AU - Moskalenko, Roman
AU - Matuła, Izabela
AU - Michalska, Joanna
AU - Jakóbik-Kolon, Agata
AU - Mishchenko, Oleg
AU - Pogorielov, Maksym
AU - Simka, Wojciech
N1 - Publisher Copyright:
© 2023 The Authors. Published by American Chemical Society.
PY - 2023/4/26
Y1 - 2023/4/26
N2 - Dental implants have become a routine, affordable, and highly reliable technology to replace tooth loss. In this regard, titanium and its alloys are the metals of choice for the manufacture of dental implants because they are chemically inert and biocompatible. However, for special cohorts of patients, there is still a need for improvements, specifically to increase the ability of implants to integrate into the bone and gum tissues and to prevent bacterial infections that can subsequently lead to peri-implantitis and implant failures. Therefore, titanium implants require sophisticated approaches to improve their postoperative healing and long-term stability. Such treatments range from sandblasting to calcium phosphate coating, fluoride application, ultraviolet irradiation, and anodization to increase the bioactivity of the surface. Plasma electrolytic oxidation (PEO) has gained popularity as a method for modifying metal surfaces and delivering the desired mechanical and chemical properties. The outcome of PEO treatment depends on the electrochemical parameters and composition of the bath electrolyte. In this study, we investigated how complexing agents affect the PEO surfaces and found that nitrilotriacetic acid (NTA) can be used to develop efficient PEO protocols. The PEO surfaces generated with NTA in combination with sources of calcium and phosphorus were shown to increase the corrosion resistance of the titanium substrate. They also support cell proliferation and reduce bacterial colonization and, hence, lead to a reduction in failed implants and repeated surgeries. Moreover, NTA is an ecologically favorable chelating agent. These features are necessary for the biomedical industry to be able to contribute to the sustainability of the public healthcare system. Therefore, NTA is proposed to be used as a component of the PEO bath electrolyte to obtain bioactive surface layers with properties desired for next-generation dental implants.
AB - Dental implants have become a routine, affordable, and highly reliable technology to replace tooth loss. In this regard, titanium and its alloys are the metals of choice for the manufacture of dental implants because they are chemically inert and biocompatible. However, for special cohorts of patients, there is still a need for improvements, specifically to increase the ability of implants to integrate into the bone and gum tissues and to prevent bacterial infections that can subsequently lead to peri-implantitis and implant failures. Therefore, titanium implants require sophisticated approaches to improve their postoperative healing and long-term stability. Such treatments range from sandblasting to calcium phosphate coating, fluoride application, ultraviolet irradiation, and anodization to increase the bioactivity of the surface. Plasma electrolytic oxidation (PEO) has gained popularity as a method for modifying metal surfaces and delivering the desired mechanical and chemical properties. The outcome of PEO treatment depends on the electrochemical parameters and composition of the bath electrolyte. In this study, we investigated how complexing agents affect the PEO surfaces and found that nitrilotriacetic acid (NTA) can be used to develop efficient PEO protocols. The PEO surfaces generated with NTA in combination with sources of calcium and phosphorus were shown to increase the corrosion resistance of the titanium substrate. They also support cell proliferation and reduce bacterial colonization and, hence, lead to a reduction in failed implants and repeated surgeries. Moreover, NTA is an ecologically favorable chelating agent. These features are necessary for the biomedical industry to be able to contribute to the sustainability of the public healthcare system. Therefore, NTA is proposed to be used as a component of the PEO bath electrolyte to obtain bioactive surface layers with properties desired for next-generation dental implants.
KW - biocompatibility
KW - complexing agent
KW - corrosion resistance
KW - dental implant
KW - plasma electrolytic oxidation
KW - surface processing
UR - https://pubs.acs.org/doi/10.1021/acsami.3c00170
UR - https://www.scopus.com/pages/publications/85152678067
U2 - 10.1021/acsami.3c00170
DO - 10.1021/acsami.3c00170
M3 - Article
C2 - 37041124
SN - 1944-8244
VL - 15
SP - 19863
EP - 19876
JO - ACS Applied Materials and Interfaces
JF - ACS Applied Materials and Interfaces
IS - 16
ER -