Pāriet uz galveno navigāciju Pāriet uz meklēšanu Pāriet uz galveno saturu

Noninvasive diagnosis of ischemia-causing coronary stenosis using CT angiography: Diagnostic value of transluminal attenuation gradient and fractional flow reserve computed from coronary CT angiography compared to invasively measured fractional flow reserve

  • Yeonyee E. Yoon
  • , Jin Ho Choi
  • , Ji Hyun Kim
  • , Kyung Woo Park
  • , Joon Hyung Doh
  • , Yong Jin Kim
  • , Bon Kwon Koo*
  • , James K. Min
  • , Andrejs Erglis
  • , Hyeon Cheol Gwon
  • , Yeon Hyeon Choe
  • , Dong Ju Choi
  • , Hyo Soo Kim
  • , Byung Hee Oh
  • , Young Bae Park
  • *Šī darba korespondējošais autors
  • Seoul National University
  • Samsung Medical Center, Sungkyunkwan university
  • Inje University
  • Cedars-Sinai Medical Center
  • Paula Stradina Clinical University Hospital

Zinātniskās darbības rezultāts: Devums žurnālamZinātniskais raksts (žurnālā)koleģiāli recenzēts

116 Atsauces (Scopus)

Kopsavilkums

Objectives: The aim of this study was to compare the diagnostic performance of coronary computed tomography angiography (CCTA)-derived computed fractional flow reserve (FFRCT) and transluminal attenuation gradient (TAG) for the diagnosis of lesion-specific ischemia. Background: Although CCTA is commonly used to detect coronary artery disease (CAD), it cannot reliably assess the functional significance of CAD. Novel technologies based on CCTA were developed to integrate anatomical and functional assessment of CAD; however, the diagnostic performance of these methods has never been compared. Methods: Fifty-three consecutive patients who underwent CCTA and coronary angiography with FFR measurement were included. Independent core laboratories determined CAD severity by CCTA, TAG, and FFRCT. The TAG was defined as the linear regression coefficient between intraluminal radiological attenuation and length from the ostium; FFRCT was computed from CCTA data using computational fluid dynamics technology. Results: Among 82 vessels, 32 lesions (39%) had ischemia by invasive FFR (FFR ≤0.80). Sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratio of TAG (≤ -0.654 HU/mm) for detection of ischemia were 38%, 88%, 67%, 69%, 3.13, and 0.71, respectively; and those of FFRCT were 81%, 94%, 90%, 89%, 13.54, and 0.20, respectively. Receiver-operating characteristic curve analysis showed a significantly larger area under the curve (AUC) for FFR CT (0.94) compared to that for TAG (0.63, p < 0.001) and CCTA stenosis (0.73, p < 0.001). In vessels with noncalcified plaque or partially calcified plaque, FFRCT showed a larger AUC (0.94) compared to that of TAG (0.63, p < 0.001) or CCTA stenosis (0.70, p < 0.001). In vessels with calcified plaque, AUC of FFRCT (0.92) was not statistically larger than that of TAG (0.75, p = 0.168) or CCTA stenosis (0.80, p = 0.195). Conclusions: Noninvasive FFR computed from CCTA provides better diagnostic performance for the diagnosis of lesion-specific ischemia compared to CCTA stenosis and TAG.

OriģinālvalodaAngļu
Lapas (no-līdz)1088-1096
Lapu skaits9
ŽurnālsJACC: Cardiovascular Imaging
Sējums5
Izdevuma numurs11
DOIs
Publikācijas statussPublicēts - nov. 2012
Ārēji publicēts

ANO IAM

Šis izpildes rezultāts palīdz sasniegt šādus ANO ilgtspējīgas attīstības mērķus (IAM)

  1. 3. IAM — Laba Veselība un Labbūtība
    3. IAM — Laba Veselība un Labbūtība

OECD Zinātnes nozare

  • 3. Medicīnas un veselības zinātnes

Nospiedums

Uzziniet vairāk par pētniecības tēmām “Noninvasive diagnosis of ischemia-causing coronary stenosis using CT angiography: Diagnostic value of transluminal attenuation gradient and fractional flow reserve computed from coronary CT angiography compared to invasively measured fractional flow reserve”. Kopā tie veido unikālu nospiedumu.

Citēt šo