Pāriet uz galveno navigāciju Pāriet uz meklēšanu Pāriet uz galveno saturu

Performance Evaluation of Machine Learning Methods for Drinking Water Contamination Detection †

  • Valts Urbanovičs*
  • , Sergei Parshutin*
  • , Jānis Rubulis*
  • , Mārtiņš Bonders
  • , Katrīna Dambeniece
  • , Roberts Ozols
  • , Dāvids Štēbelis
  • , Sandis Dejus*
  • *Šī darba korespondējošais autors
  • Rīgas Tehniskā universitāte
  • Waterson Technologies OÜ

Zinātniskās darbības rezultāts: Devums žurnālam › Zinātniskais raksts (žurnālā) › koleģiāli recenzēts

Kopsavilkums

The aim of the study is to train a machine learning (ML) model for drinking water contamination detection and compare performance to statistical methods and existing anomaly detection solutions. A pilot drinking water supply system was made and equipped with drinking water quality sensors and a contamination dosing system. The results from this study demonstrated that using the statistical Mahalanobis distance (MD) method to predict the classification of drinking water measurements yields a 99% accuracy, 23% precision, and 28% F-score result (for wastewater contamination); however, the ML model yields a 99% accuracy, 98% precision, and a 98% F-score result. The results show that the application of ML methods can improve drinking water contamination detection speed and accuracy.

OriģinālvalodaAngļu
Raksta numurs110
ŽurnālsEngineering Proceedings
Sējums69
Izdevuma numurs1
DOIs
Publikācijas statussPublicēts - 2024
Ārēji publicētsJā

ANO IAM

Šis izpildes rezultāts palīdz sasniegt šādus ANO ilgtspējīgas attīstības mērķus (IAM)

  1. 6. IAM — Tīrs Ūdens un Sanitārija
    6. IAM — Tīrs Ūdens un Sanitārija

Nospiedums

Uzziniet vairāk par pētniecības tēmām “Performance Evaluation of Machine Learning Methods for Drinking Water Contamination Detection †”. Kopā tie veido unikālu nospiedumu.

Citēt šo