Preliminary demonstration on JET of an ITER neutron environment-compatible quadrupole mass-spectrometer

  • Līga Avotiņa (Darba grupas dalībnieks)
  • , Larisa Baumane (Darba grupas dalībnieks)
  • , Mihails Haļitovs (Darba grupas dalībnieks)
  • , Juris Jansons (Darba grupas dalībnieks)
  • , Gunta Ķizāne (Darba grupas dalībnieks)
  • , Ričards Kovaldins (Darba grupas dalībnieks)
  • , Andris Leščinskis (Darba grupas dalībnieks)
  • , Broņislavs Leščinskis (Darba grupas dalībnieks)
  • , Elīna Pajuste (Darba grupas dalībnieks)
  • , Aigars Vītiņš (Darba grupas dalībnieks)
  • , Artūrs Zariņš (Darba grupas dalībnieks)
  • , Klepper C.C.
  • , JET Contributors

    Zinātniskās darbības rezultāts: Devums žurnālam › Zinātniskais raksts (žurnālā) › koleģiāli recenzēts

    3 Atsauces (Scopus)

    Kopsavilkums

    Strict limits recently imposed on neutron exposure to electronics for critical diagnostic systems on ITER, the fusion reactor demonstration facility under construction in the south of France, has led to the development of a quadrupole mass spectrometer with an exceptionally long cable. An 80 m cable exceeds the last state-of-the art limit of 15 m, imposed by the normally required proximity of the RF supply to the analyzer, and will allow locating the electronics in a neutron safe environment. This breakthrough, a joint development of ORNL with Hiden Analytical Ltd., was enabled by the use of an intermediate, RF-matching unit, free of silicon-based electronics, and using only vacuum tubes and an air-core transformer, rendering it resilient both to ionizing radiation and to fringing magnetic fields. After successful testing of the prototype unit, both at ORNL and Hiden's laboratories, the unit was installed on the JET tokamak, as part of a multi-sensor, divertor effluent gas analysis system, similar to one also under design for ITER. As such, the prototype will be tested both before and during the next nuclear (D-T) operation of JET, planned for mid-2021. In this paper, the prototype development, laboratory testing and first results from non-nuclear plasma pulse testing on JET are presented. The latter include not only successful detection of fusion fuel cycle and impurity species, but also improved resolution and stability over the state-of-the-art, 15m-cable units on the same analysis station.

    OriģinālvalodaAngļu
    Raksta numurs112672
    ŽurnālsFusion Engineering and Design
    Sējums170
    DOIs
    Publikācijas statussPublicēts - sept. 2021

    ANO IAM

    Šis izpildes rezultāts palīdz sasniegt šādus ANO ilgtspējīgas attīstības mērķus (IAM)

    1. 7. IAM — Tīra Enerģija par Pieejamu Cenu
      7. IAM — Tīra Enerģija par Pieejamu Cenu

    OECD Zinātnes nozare

    • 1.3 Fizika un astronomija

    Nospiedums

    Uzziniet vairāk par pētniecības tēmām “Preliminary demonstration on JET of an ITER neutron environment-compatible quadrupole mass-spectrometer”. Kopā tie veido unikālu nospiedumu.

    Citēt šo