TY - JOUR
T1 - Real-time antiproton annihilation vertexing with submicrometer resolution
AU - AEḡIS Collaboration
AU - Berghold, Michael
AU - Orsucci, Davide
AU - Guatieri, Francesco
AU - Alfaro, Sara
AU - Auziņš, Mārcis
AU - Bergmann, Benedikt
AU - Burian, Petr
AU - Brusa, Roberto Sennen
AU - Camper, Antoine
AU - Caravita, Ruggero
AU - Castelli, Fabrizio
AU - Cerchiari, Giovanni
AU - Ciuryło, Roman Jerzy
AU - Chehaimi, Ahmad
AU - Consolati, Giovanni
AU - Doser, Michael
AU - Eliaszuk, Kamil
AU - Ferguson, Riley Craig
AU - Germann, Matthias
AU - Giszczak, Anna
AU - Glöggler, Lisa
AU - Graczykowski, Łukasz
AU - Grosbart, Malgorzata
AU - Gusakova, Natali
AU - Gustafsson, Fredrik
AU - Haider, Stefan
AU - Huck, Saiva
AU - Hugenschmidt, Christoph
AU - Janik, Malgorzata Anna
AU - Januszek, Tymoteusz Henryk
AU - Kasprowicz, Grzegorz
AU - Kempny, Kamila
AU - Khatri, Ghanshyambhai
AU - Kłosowski, Łukasz
AU - Kornakov, Georgy
AU - Krūmiņš, Valts
AU - Lappo, Lidia
AU - Linek, Adam
AU - Mariazzi, Sebastiano
AU - Moskal, Pawel
AU - Nowicka, Dorota
AU - Pandey, Piyush
AU - PĘcak, Daniel
AU - Penasa, Luca
AU - Petracek, Vojtech
AU - Piwiński, Mariusz
AU - Pospisil, Stanislav
AU - Povolo, Luca
AU - Prelz, Francesco
AU - Rangwala, Sadiqali
N1 - Publisher Copyright:
Copyright © 2025 The Authors, some rights reserved;
PY - 2025/4/4
Y1 - 2025/4/4
N2 - Primary goal of the AEḡIS experiment is to precisely measure the free fall of antihydrogen within Earth’s gravitational field. To this end, cold (≈ 50 K) antihydrogen will traverse a two-grid moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here, we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations within 0.62+−0.400.22 μm, a 35-fold improvement over the previous state of the art for real-time antiproton vertexing. These methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables in situ calibration of the moiré deflectometer, substantially reducing systematic errors. This sensor emerges as a breakthrough technology toward the AEḡIS scientific goals and will constitute the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
AB - Primary goal of the AEḡIS experiment is to precisely measure the free fall of antihydrogen within Earth’s gravitational field. To this end, cold (≈ 50 K) antihydrogen will traverse a two-grid moiré deflectometer before annihilating onto a position-sensitive detector, which shall determine the vertical position of the annihilation vertex relative to the grids with micrometric accuracy. Here, we introduce a vertexing detector based on a modified mobile camera sensor and experimentally demonstrate that it can measure the position of antiproton annihilations within 0.62+−0.400.22 μm, a 35-fold improvement over the previous state of the art for real-time antiproton vertexing. These methods are directly applicable to antihydrogen. Moreover, the sensitivity to light of the sensor enables in situ calibration of the moiré deflectometer, substantially reducing systematic errors. This sensor emerges as a breakthrough technology toward the AEḡIS scientific goals and will constitute the basis for the development of a large-area detector for conducting antihydrogen gravity measurements.
KW - Annihilation
KW - Gravitational effects
KW - Photons
KW - Antihydrogen
UR - https://www.science.org/doi/10.1126/sciadv.ads1176
UR - https://www.scopus.com/pages/publications/105001844097
U2 - 10.1126/sciadv.ads1176
DO - 10.1126/sciadv.ads1176
M3 - Article
C2 - 40173232
AN - SCOPUS:105001844097
SN - 2375-2548
VL - 11
JO - Science Advances
JF - Science Advances
IS - 14
M1 - eads1176
ER -