Pāriet uz galveno navigāciju Pāriet uz meklēšanu Pāriet uz galveno saturu

Reversible and irreversible effects on the epoxy GFRP fiber-matrix interphase due to hydrothermal aging

  • Andrey E. Krauklis*
  • , Olesja Starkova
  • , Dennis Gibhardt
  • , Gerhard Kalinka
  • , Hani Amir Aouissi
  • , Juris Burlakovs
  • , Alisa Sabalina
  • , Bodo Fiedler
  • *Šī darba korespondējošais autors
  • Hamburg University of Technology
  • Federal Institute for Materials Research and Testing Berlin
  • Scientific and Technical Research Center on Arid Regions (CRSTRA)
  • University of Science and Technology Houari Boumediene
  • Badji Mokhtar University
  • Estonian University of Life Sciences
  • University of Latvia

Zinātniskās darbības rezultāts: Devums žurnālamZinātniskais raksts (žurnālā)koleģiāli recenzēts

26 Atsauces (Scopus)

Kopsavilkums

Epoxy R-Glass Fiber-Reinforced Polymer (GFRP) composite plates were hydrothermally aged at 60 °C for 23, 75, and 133 days. The water content reached 0.97 wt%, 1.45 wt% and 1.63 wt%, respectively. The studied GFRP matrix was inert to hydrolysis or chain scission, allowing for investigation of irreversible changes in the fiber-matrix interphase due to hydrothermal aging upon re-drying. During each period, a subset of the specimens was removed from the water bath and dried in a chamber. The weight loss upon drying was explained with epoxy leaching (impurities), sizing-rich interphase hydrolysis, glass fiber surface hydrolysis, accumulated degradation products escaping, and water changing state from bound to free. The influence of hydrothermal aging on the fiber-matrix interfacial properties was investigated. Lower interfacial strength of hydrothermally aged (wet) samples was attributed to plasticization of the epoxy, plasticization and degradation of the sizing-rich interphase (including formation of hydrolytic flaws), and hydrolytic degradation of the glass fiber surface. The kinetics of epoxy-compatible epoxysilane W2020 sizing-rich interphase hydrolysis provided an estimate of ca. 1.49%, 4.80%, and 8.49% of the total composite interphase degraded after 23, 75, and 133 days, respectively. At these conditions, the interface lost 39%, 48%, and 51% of its strength. Upon re-drying the specimens, a significant part of the interfacial strength was regained. Furthermore, an upward trend was observed, being 13%, 10% and 3% strength, respectively; thus, indicating a possibility of partial recovery of properties.

OriģinālvalodaAngļu
Raksta numurs100395
ŽurnālsComposites Part C: Open Access
Sējums12
DOIs
Publikācijas statussPublicēts - okt. 2023

Nospiedums

Uzziniet vairāk par pētniecības tēmām “Reversible and irreversible effects on the epoxy GFRP fiber-matrix interphase due to hydrothermal aging”. Kopā tie veido unikālu nospiedumu.

Citēt šo