Pāriet uz galveno navigāciju Pāriet uz meklēšanu Pāriet uz galveno saturu

Transcatheter reshaping of the mitral annulus in patients with functional mitral regurgitation: One-year outcomes of the MAVERIC trial

  • Stephen Worthley
  • , Simon Redwood
  • , David Hildick-Smith
  • , Tony Rafter
  • , Alan Whelan
  • , Federico Demarco
  • , Mark Horrigan
  • , Sinny Delacroix*
  • , John Gregson
  • , Andrejs Erglis
  • *Šī darba korespondējošais autors
  • St Andrews Hospital
  • GenesisCare
  • St Thomas’Hospital
  • Brighton and Sussex NHS Trust Brighton
  • Heart Care Partners
  • HeartCare WA
  • IRCCS Policlinico San Donato
  • Austin Health
  • London School of Hygiene and Tropical Medicine
  • Paula Stradina Clinical University Hospital

Zinātniskās darbības rezultāts: Devums žurnālam › Zinātniskais raksts (žurnālā) › koleģiāli recenzēts

17 Atsauces (Scopus)

Kopsavilkums

Aims: The aim of this study was to assess the one-year safety and efficacy of the transcatheter ARTO system in the treatment of functional mitral regurgitation (FMR). Methods and results: MAVERIC is a multicentre, prospective, non-randomised pre-commercial study. Eligible patients were on guideline-recommended therapy for NYHA Class II-IV systolic heart failure and had an FMR grade ≥2+. The ARTO system was implanted in forty-five (100%) patients. The primary safety composite endpoint (death, stroke, myocardial infarction, device-related surgery, cardiac tamponade, renal failure) at 30 days and one year was 4.4% (95% CI: 1.5-16.6) and 17.8% (95% CI: 9.3-32.4), respectively. Periprocedural complications occurred in seven patients (15.5% [95% CI: 6.5-29.5]), and five patients (11.1% [95% CI: 4.9-24.0]) died during one-year follow-up. Paired results for 36 patients demonstrated that 24 (66.7%) had grade 3+/4+ mitral regurgitation at baseline; however, only five (13.9%) and three (8.3%) patients remained at grade 3+/4+ 30 days and one year post procedure (p<0.0001). Echocardiographic parameters such as anteroposterior annulus diameter decreased from 41.4 mm (baseline) to 36.0 and 35.3 mm at 30 days and one year, respectively (p<0.0001). Twenty-five patients (69.4%) had baseline NYHA Class III/IV symptoms decreasing significantly to nine (25.0%) at 30 days and eight (22.2%) at one year post procedure (p<0.0001). Conclusions: The ARTO transcatheter mitral valve repair system is both safe and effective in decreasing FMR up to one year post procedure.

OriģinālvalodaAngļu
Lapas (no-līdz)1106-1113
Lapu skaits8
ŽurnālsEuroIntervention
Sējums16
Izdevuma numurs13
DOIs
Publikācijas statussPublicēts - 2021
Ārēji publicētsJā

ANO IAM

Šis izpildes rezultāts palīdz sasniegt šādus ANO ilgtspējīgas attīstības mērķus (IAM)

  1. 3. IAM — Laba Veselība un Labbūtība
    3. IAM — Laba Veselība un Labbūtība

Nospiedums

Uzziniet vairāk par pētniecības tēmām “Transcatheter reshaping of the mitral annulus in patients with functional mitral regurgitation: One-year outcomes of the MAVERIC trial”. Kopā tie veido unikālu nospiedumu.

Citēt šo