Kopsavilkums
The contribution of static and thermal disorder is one of the largest challenges for the accurate determination of the atomic structure from the extended X-ray absorption fine structure (EXAFS). Although there are a number of generally accepted approaches to solve this problem, which are widely used in the EXAFS data analysis, they often provide less accurate results when applied to outer coordination shells around the absorbing atom. In this case, the advanced techniques based on the molecular dynamics and reverse Monte Carlo simulations are known to be more appropriate: their strengths and weaknesses are reviewed here.
| Oriģinālvaloda | Angļu |
|---|---|
| Raksta numurs | 108112 |
| Lapas (no-līdz) | 1-8 |
| Žurnāls | Radiation Physics and Chemistry |
| Sējums | 175 |
| DOIs | |
| Publikācijas statuss | Publicēts - okt. 2020 |
OECD Zinātnes nozare
- 1.3 Fizika un astronomija
Nospiedums