Pāriet uz galveno navigāciju Pāriet uz meklēšanu Pāriet uz galveno saturu

Tunable liquid lens equipped virtual reality adapter for scientific, medical, and therapeutic goals

  • University of Latvia

Zinātniskās darbības rezultāts: Nodaļa grāmatā/enciklopēdijā/konferences krājumā › Konferences zinātniskais raksts › Pētniecība › koleģiāli recenzēts

2 Atsauces (Scopus)

Kopsavilkums

We adapted virtual reality appliances to use them in scientific medical diagnostics and therapeutic aims by incorporated as part of appliance ocular system two electrically tunable Optotune liquid lenses, controllable by computer USB ports within 20D range. In present time we used the appliance to investigate the mono- and/or binocularly illusory perception dominances (Shapiro and al;2008), nonlinearities caused by controversial Gestalt recognition of motion. Back layer of stimuli elements contained internal motion sources - clockwise spinning disk on neutral background. Disk consisted of centrosymmetric radial rays which luminance was sinus mode modulated along the disc circumference. Spinning speed was 0.15 rps. Spatial frequencies of modulation were within the range 1.8-3.7 cpd. Frontal stimuli layer contained concentrically allocated six circular apertures in neutral background rotating with the same speed however counterclockwise. Apertures lied concentrically with symmetry center collocated with the hidden center of internal motion. Observers made judgements (T observ =2sec) at different viewing eccentricity: 1) movement of disks seemed jumbled; spinning perceived continuous, however 2) counter- or 3) clockwise. Illusory perception - clockwise perception of movement sets on when viewing peripherally. Favorable conditions of that are equality of the frontal stimuli layer luminance to mean luminance of modulations, increasing contrast of modulations and increasing viewing eccentricity. Increasing of modulation spatial frequency diminishes illusion onset probability. Virtual reality appliances completed with tunable liquid lenses electrically controlling defocus allow to perform such experiments and to check patients with unilateral eye cataract.

OriģinālvalodaAngļu
Publikācijas avota nosaukumsOptoelectronic Imaging and Multimedia Technology V
RedaktoriQionghai Dai, Tsutomu Shimura
IzdevējsSPIE
ISBN (Elektroniski)9781510622326
DOIs
Publikācijas statussPublicēts - 2018
PasākumsOptoelectronic Imaging and Multimedia Technology V 2018 - Beijing, Ķīna
Ilgums: 11 okt. 2018 → 12 okt. 2018

Publikāciju sērijas

NosaukumsProceedings of SPIE - The International Society for Optical Engineering
Sējums10817
ISSN (Drukātā versija)0277-786X
ISSN (Elektroniskā versija)1996-756X

Konference

KonferenceOptoelectronic Imaging and Multimedia Technology V 2018
Valsts/TeritorijaĶīna
PilsētaBeijing
Periods11/10/18 → 12/10/18

Nospiedums

Uzziniet vairāk par pētniecības tēmām “Tunable liquid lens equipped virtual reality adapter for scientific, medical, and therapeutic goals”. Kopā tie veido unikālu nospiedumu.

Citēt šo